howtos:model_loading [2009/10/23 20:01]
deryn.crockett created
howtos:model_loading [2011/02/18 20:36]
deryn.crockett
Line 1: Line 1:
-====== ​How to Load a Model from Documenter into SAMM ====== +====== Model loading: When you have a simulator AND calibrator ​======
 ===== Prepare for loading from inside Documenter ===== ===== Prepare for loading from inside Documenter =====
-1. Ensure the calibrator and simulator diagrams are synchronized +  -Ensure the calibrator and simulator diagrams are synchronized 
-1. Open the calibrator ​diagram & simulator diagrams in Documenter +  -Open the calibrator ​and simulator diagrams in Documenter 
-2. Touch the informants and measures in the calibrator diagram to trigger the model to output the informants +  ​-In ​the simulator diagram, run one calculator forward 
-  ​a. ​Go into any one informant under the informants tab and click OK +  -In the calibrator diagram, touch the informants and measures ​to trigger the model to output the informants 
-  ​b. ​Go into any measure under the measures tab and click OK +    -Go into any one informant under the informants tab and click OK 
-  **Note:** The calibrator versions of the informants and measures are the authority versions and the simulator ones may get out of sync+    -Go into any measure under the measures tab and click OK 
 +    -Note: The calibrator versions of the informants and measures are the authority versions and the simulator ones may get out of sync 
 +  -In the calibrator diagram, run all calculators forward 
 +  -In the simulator diagram, run all calculators forward 
 +  -In the simulator diagram, run all calculators backward 
 +  -In the simulator diagram, create the loading files for SAMM  
 +    -Choose menu item SAMM > Loading files > Framework... 
 +    -Click "​simulator with calibrator"​ button 
 +    -Make sure the "​informants"​ check box is OFF!! 
 +    -Click OK 
 +  -In the calibrator diagram, create the loading files for SAMM 
 +    -Choose menu item SAMM > Loading files > Framework... 
 +    -Click "​calibrator"​ button 
 +    -Make sure the "​informants"​ check box is ON!! 
 +    -Click OK
  
-2. Simulator - Run one calculator forward +===== Load model inside SAMM =====
-3. Calibrator - go into the informants, look at one and click OK. +
-4. Calibrator - go into the measures, look at one and click OK. +
-5. Calibrator - run all forward +
-6. Simulator - run all forward +
-7. Simulator - run all backward +
-8. Simulator - make "​simulator with calibrato"​r loading files (NO informants)+
  
-    ​a. Choose menu item SAMM/Loading ​files/Framework... +  -Open SAMM and login under model account 
-    ​b. Click "​simulator with calibrator"​ button +  -Create ​new model family  
-    ​c. Make sure the "informant" check box is OFF!!+    -Choose menu item MF Actions > Create OR right click in Model Families window and choose Create 
 +    -"MB name" should be a string with no spaces or strange characters It is often related to the ModelBase name in the root of the model but it does not have to be. 
 +    -Fill in an English description. 
 +    -Click OK 
 +  -Enter the Model Family by double clicking on it.  A check mark appears in the Model Families window. 
 +  -Setup the default file path 
 +    -Choose menu item File > Set File Path... 
 +    -This is a unix style path so use forward slashes and direct it to the location of the simulator files (e.g. /models/​tcteem/​V5/​sim) 
 +  -Load the simulator and calibrator frameworks 
 +    -Choose menu item FW Actions > Load OR right click and select Load (note the location is what you set in step 4) 
 +    -MB name: MUST be the model base name from the root of the simulation diagram, give it the description “sim” 
 +    -Click OK to load the simulation framework 
 +    -Choose menu item File > Set File Path... and direct it to the location of the calibrator ​files (e.g. /models/​tcteem/​V5/​cal) 
 +    -Choose menu item FW Actions > Load OR right click and select Load again 
 +    -Enter the MB name from the calibration diagram, and enter "​cal"​ as the description 
 +    -Activate the calibration framework check box 
 +    -Click OK to load the calibration framework 
 +  -Load informants 
 +    -Choose menu item Windows > Informants 
 +    -Choose menu item Informant Actions > Load OR right click in Informants window and select Load 
 +    -Ensure the file path points to the cal location (the path should read something like /​models/​tcteem/​V5/​cal/​informs.samm) 
 +    -Click OK to load the informants 
 + 
 + 
 +===== Run Calibration to Produce a History ===== 
 +This part of the process depends on your individual model By convention we keep a loading recipe in the notes for the root node in the diagram In Documentor right click on the root node and go to Properties, then choose the notes button. ​ Here's a template of how to run the recipe and produce a hisotry: 
 +  -Load the views in the views window 
 +    ​-Setup the default file path to the views directory (e.g. /​models/​tcteem/​V5/​cal/​views) 
 +    -Choose menu item View Actions > Load OR right click and select Load 
 +  -Follow the recipe which will likely involve loading a source history, running some feedback views and saving scenarios as you go and the final one will be your tracking history. 
 +  -Evaluate history ins for your tracking history - this prepares all the calibrator inputs and data needed for the simulator to be run over historic time 
 +    -Right click on the tracking history scenario in the scenarios window and choose "​Evaluate history inputs"​ 
 +  -Evaluate history outputs for your tracking history - this runs the simulator frame work over historic time and produces the history scenario 
 +    -Right click on the tracking history scenario in the scenarios window and choose "​Evaluate history outputs"​ 
 +    -Name your historic scenario, we usually just use the name "​history"​ - this will show up in the simulation frame work  
 + 
 +====== Model loading: When you have a simulator ONLY ====== 
 +===== Prepare for loading from inside Documenter ===== 
 +  -Open the simulator diagram in Documenter 
 +  -Touch the informants and measures to trigger the model to output the informants 
 +    -Go into any one informant under the informants tab and click OK 
 +    -Go into any measure under the measures tab and click OK 
 +  -Run all calculators forward 
 +  -Run all calculators backward 
 +  -Create the loading files for SAMM  
 +    -Choose menu item SAMM > Loading files > Framework... 
 +    -Click "​simulator with calibrator"​ button 
 +    ​-Select ​the "informants" ​check box so that check box is ON 
 +    -Click OK
  
 +===== Load model inside SAMM =====
  
-9. Calibrator ​make "calibrator" ​loading ​files+  -Open SAMM and login under model account 
 +  -Create a new model family  
 +    -Choose menu item MF Actions > Create OR right click in Model Families window and choose Create 
 +    ​-"MB name" ​should be a string with no spaces or strange characters. ​ It is often related to the ModelBase name in the root of the model but it does not have to be. 
 +    -Fill in an English description. 
 +    -Click OK 
 +  -Enter the Model Family by double clicking on it.  A check mark appears in the Model Families window. 
 +  -Setup the default file path 
 +    -Choose menu item File > Set File Path... 
 +    -This is a unix style path so use forward slashes and direct it to the location of the simulator ​files (e.g. /​models/​tcteem/​V5/​sim) 
 +  -Load the simulator framework 
 +    -Choose menu item FW Actions > Load OR right click and select Load (note the location is what you set in step 4) 
 +    -MB name: MUST be the model base name from the root of the simulation diagram, give it the description “sim” 
 +  -Load informants 
 +    -Choose menu item Windows > Informants 
 +    -Right click and select Load (path should be correct because of 5c) 
 +    -Adjust the file location if it is incorrect (should be something like /​models/​tcteem/​V5/​sim/​informs.samm)
  
-    a. Choose menu item SAMM/​Loading files/​Framework... 
-    b. Click "​calibrator"​ button 
-    c. Make sure the "​informant"​ check box is ON!! 