User Tools

Site Tools


howtos:model_loading

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
howtos:model_loading [2009/12/01 14:28]
shona.weldon
howtos:model_loading [2011/01/12 20:48]
chris.strashok
Line 1: Line 1:
-====== ​How to Load a Model from Documenter into SAMM ====== +====== Model loading: When you have a simulator AND calibrator ​======
 ===== Prepare for loading from inside Documenter ===== ===== Prepare for loading from inside Documenter =====
   -Ensure the calibrator and simulator diagrams are synchronized   -Ensure the calibrator and simulator diagrams are synchronized
-  -Open the calibrator ​diagram & simulator diagrams in Documenter+  -Open the calibrator ​and simulator diagrams in Documenter
   -In the simulator diagram, run one calculator forward   -In the simulator diagram, run one calculator forward
   -In the calibrator diagram, touch the informants and measures to trigger the model to output the informants   -In the calibrator diagram, touch the informants and measures to trigger the model to output the informants
Line 28: Line 27:
   -Create a new model family ​   -Create a new model family ​
     -Choose menu item MF Actions > Create OR right click in Model Families window and choose Create     -Choose menu item MF Actions > Create OR right click in Model Families window and choose Create
-    -"MB name" should be a string with no spaces or strange characters. ​ It is Often related to the ModelBase name in the root of the model but it does not have to be.+    -"MB name" should be a string with no spaces or strange characters. ​ It is often related to the ModelBase name in the root of the model but it does not have to be.
     -Fill in an English description.     -Fill in an English description.
     -Click OK     -Click OK
Line 38: Line 37:
     -Choose menu item FW Actions > Load OR right click and select Load (note the location is what you set in step 4)     -Choose menu item FW Actions > Load OR right click and select Load (note the location is what you set in step 4)
     -MB name: MUST be the model base name from the root of the simulation diagram, give it the description “sim”     -MB name: MUST be the model base name from the root of the simulation diagram, give it the description “sim”
-    -Adjust ​your default file path to the cal location (e.g. /​models/​tcteem/​V5/​cal) +    -Click OK to load the simulation framework 
-    -Repeat loading framework for cal BUT choose the check button to say it is a calibration framework, use the MB name from the calibration diagram, and enter "​cal"​ as the description+    -Choose menu item FW Actions > Load OR right click and select Load again (note you need to adjust ​your default file path to the cal location (e.g. /​models/​tcteem/​V5/​cal) 
 +    -Enter the MB name from the calibration diagram, and enter "​cal"​ as the description 
 +    -Activate the calibration framework check box 
 +    -Click OK to load the calibration framework
   -Load informants   -Load informants
     -Choose menu item Windows > Informants     -Choose menu item Windows > Informants
-    -Right click and select Load (path should be correct because of 5c) +    -Ensure ​the file path points to the cal location (the path should ​read something like /​models/​tcteem/​V5/​cal/​informs.samm)
-    -Adjust ​the file location ​if it is incorrect ​(should ​be something like /​models/​tcteem/​V5/​cal/​informs.samm)+
  
 ===== Run Calibration to Produce a History ===== ===== Run Calibration to Produce a History =====
Line 57: Line 58:
     -Name your historic scenario, we usually just use the name "​history"​ - this will show up in the simulation frame work      -Name your historic scenario, we usually just use the name "​history"​ - this will show up in the simulation frame work 
  
 +====== Model loading: When you have a simulator ONLY ======
 +===== Prepare for loading from inside Documenter =====
 +  -Open the simulator diagram in Documenter
 +  -Touch the informants and measures to trigger the model to output the informants
 +    -Go into any one informant under the informants tab and click OK
 +    -Go into any measure under the measures tab and click OK
 +  -Run all calculators forward
 +  -Run all calculators backward
 +  -Create the loading files for SAMM 
 +    -Choose menu item SAMM > Loading files > Framework...
 +    -Click "​simulator with calibrator"​ button
 +    -Select the "​informants"​ check box so that check box is ON
 +    -Click OK
 +
 +===== Load model inside SAMM =====
 +
 +  -Open SAMM and login under model account
 +  -Create a new model family ​
 +    -Choose menu item MF Actions > Create OR right click in Model Families window and choose Create
 +    -"MB name" should be a string with no spaces or strange characters. ​ It is often related to the ModelBase name in the root of the model but it does not have to be.
 +    -Fill in an English description.
 +    -Click OK
 +  -Enter the Model Family by double clicking on it.  A check mark appears in the Model Families window.
 +  -Setup the default file path
 +    -Choose menu item File > Set File Path...
 +    -This is a unix style path so use forward slashes and direct it to the location of the simulator files (e.g. /​models/​tcteem/​V5/​sim)
 +  -Load the simulator framework
 +    -Choose menu item FW Actions > Load OR right click and select Load (note the location is what you set in step 4)
 +    -MB name: MUST be the model base name from the root of the simulation diagram, give it the description “sim”
 +  -Load informants
 +    -Choose menu item Windows > Informants
 +    -Right click and select Load (path should be correct because of 5c)
 +    -Adjust the file location if it is incorrect (should be something like /​models/​tcteem/​V5/​sim/​informs.samm)
  
howtos/model_loading.txt · Last modified: 2011/02/18 20:36 by deryn.crockett