howtos:model_loading [2009/10/23 20:13]
deryn.crockett
howtos:model_loading [2011/02/18 20:36] (current)
deryn.crockett
Line 1: Line 1:
-====== ​How to Load a Model from Documenter into SAMM ====== +====== Model loading: When you have a simulator AND calibrator ​======
 ===== Prepare for loading from inside Documenter ===== ===== Prepare for loading from inside Documenter =====
-1. Ensure the calibrator and simulator diagrams are synchronized+  -Ensure the calibrator and simulator diagrams are synchronized 
 +  -Open the calibrator and simulator diagrams in Documenter 
 +  -In the simulator diagram, run one calculator forward 
 +  -In the calibrator diagram, touch the informants and measures to trigger the model to output the informants 
 +    -Go into any one informant under the informants tab and click OK 
 +    -Go into any measure under the measures tab and click OK 
 +    -Note: The calibrator versions of the informants and measures are the authority versions and the simulator ones may get out of sync 
 +  -In the calibrator diagram, run all calculators forward 
 +  -In the simulator diagram, run all calculators forward 
 +  -In the simulator diagram, run all calculators backward 
 +  -In the simulator diagram, create the loading files for SAMM  
 +    -Choose menu item SAMM > Loading files > Framework... 
 +    -Click "​simulator with calibrator"​ button 
 +    -Make sure the "​informants"​ check box is OFF!! 
 +    -Click OK 
 +  -In the calibrator diagram, create the loading files for SAMM 
 +    -Choose menu item SAMM > Loading files > Framework... 
 +    -Click "​calibrator"​ button 
 +    -Make sure the "​informants"​ check box is ON!! 
 +    -Click OK
  
-2. Open the calibrator diagram & simulator diagrams in Documenter+===== Load model inside SAMM =====
  
-3In the simulator diagram, ​run one calculator forward+  -Open SAMM and login under model account 
 +  -Create a new model family  
 +    -Choose menu item MF Actions > Create OR right click in Model Families window and choose Create 
 +    -"MB name" should be a string with no spaces or strange characters It is often related to the ModelBase name in the root of the model but it does not have to be. 
 +    -Fill in an English description. 
 +    -Click OK 
 +  -Enter the Model Family by double clicking on it.  A check mark appears in the Model Families window. 
 +  -Setup the default file path 
 +    -Choose menu item File > Set File Path... 
 +    -This is a unix style path so use forward slashes and direct it to the location of the simulator ​files (e.g. /​models/​tcteem/​V5/​sim) 
 +  -Load the simulator and calibrator frameworks 
 +    -Choose menu item FW Actions > Load OR right click and select Load (note the location is what you set in step 4) 
 +    -MB name: MUST be the model base name from the root of the simulation ​diagram, ​give it the description “sim” 
 +    -Click OK to load the simulation framework 
 +    -Choose menu item File > Set File Path... and direct it to the location of the calibrator files (e.g. /​models/​tcteem/​V5/​cal) 
 +    -Choose menu item FW Actions > Load OR right click and select Load again 
 +    -Enter the MB name from the calibration diagram, and enter "​cal"​ as the description 
 +    -Activate the calibration framework check box 
 +    -Click OK to load the calibration framework 
 +  -Load informants 
 +    -Choose menu item Windows > Informants 
 +    -Choose menu item Informant Actions > Load OR right click in Informants window and select Load 
 +    -Ensure the file path points to the cal location (the path should read something like /​models/​tcteem/​V5/​cal/​informs.samm) 
 +    -Click OK to load the informants
  
-4. In the calibrator diagram, touch the informants and measures to trigger the model to output the informants 
  
-   a. Go into any one informant under the informants tab and click OK +===== Run Calibration to Produce ​History ===== 
-   b. Go into any measure under the measures tab and click OK +This part of the process depends on your individual model. ​ By convention we keep a loading recipe in the notes for the root node in the diagram. ​ In Documentor right click on the root node and go to Propertiesthen choose the notes button. ​ Here's a template of how to run the recipe and produce a hisotry: 
- +  ​-Load ​the views in the views window 
- ​**Note:​** The calibrator versions ​of the informants and measures are the authority versions and the simulator ones may get out of sync +    ​-Setup ​the default file path to the views directory (e.g. /​models/​tcteem/​V5/​cal/​views) 
- +    ​-Choose menu item View Actions ​Load OR right click and select Load 
-5. In the calibrator ​diagram, run all calculators forward +  -Follow the recipe which will likely involve loading a source history, running some feedback views and saving scenarios as you go and the final one will be your tracking history. 
- +  -Evaluate history ins for your tracking history - this prepares all the calibrator inputs and data needed for the simulator to be run over historic time 
-6. In the simulator diagram, run all calculators forward +    ​-Right click on the tracking history scenario in the scenarios window and choose ​"Evaluate history inputs" 
- +  -Evaluate history outputs for your tracking history - this runs the simulator frame work over historic time and produces the history scenario 
-7. In the simulator diagram, run all calculators backward +    ​-Right click on the tracking history scenario in the scenarios window and choose ​"Evaluate history outputs
- +    ​-Name your historic scenario, we usually just use the name "​history"​ - this will show up in the simulation frame work 
-8. In the simulator diagram, create ​the loading files for SAMM  +
- +
-    ​a. Choose menu item SAMM Loading files > Framework..+
-    ​b. Click "simulator with calibrator" ​button +
-    ​c. Make sure the "informant" ​check box is OFF!! +
-    ​d. Click OK+
  
 +====== Model loading: When you have a simulator ONLY ======
 +===== Prepare for loading from inside Documenter =====
 +  -Open the simulator diagram in Documenter
 +  -Touch the informants and measures to trigger the model to output the informants
 +    -Go into any one informant under the informants tab and click OK
 +    -Go into any measure under the measures tab and click OK
 +  -Run all calculators forward
 +  -Run all calculators backward
 +  -Create the loading files for SAMM 
 +    -Choose menu item SAMM > Loading files > Framework...
 +    -Click "​simulator with calibrator"​ button
 +    -Select the "​informants"​ check box so that check box is ON
 +    -Click OK
  
-9. In the calibrator diagram, create the loading files for SAMM+===== Load model inside ​SAMM =====
  
-    ​aChoose menu item SAMM Loading files > Framework... +  -Open SAMM and login under model account 
-    ​b. Click "​calibrator"​ button +  -Create ​new model family  
-    ​cMake sure the "​informant"​ check box is ON!! +    -Choose menu item MF Actions ​Create OR right click in Model Families window and choose Create 
-    ​dClick OK+    -"MB name" should be a string with no spaces or strange characters It is often related to the ModelBase name in the root of the model but it does not have to be
 +    ​-Fill in an English description. 
 +    -Click OK 
 +  -Enter the Model Family by double clicking on it.  A check mark appears in the Model Families window. 
 +  -Setup the default file path 
 +    ​-Choose menu item File > Set File Path... 
 +    -This is a unix style path so use forward slashes and direct it to the location of the simulator files (e.g. /​models/​tcteem/​V5/​sim) 
 +  -Load the simulator framework 
 +    -Choose menu item FW Actions > Load OR right click and select Load (note the location ​is what you set in step 4) 
 +    ​-MB name: MUST be the model base name from the root of the simulation diagram, give it the description “sim” 
 +  -Load informants 
 +    -Choose menu item Windows > Informants 
 +    -Right click and select Load (path should be correct because of 5c) 
 +    -Adjust the file location if it is incorrect (should be something like /​models/​tcteem/​V5/​sim/​informs.samm)
  
howtos/model_loading.1256328804.txt.gz · Last modified: 2009/10/23 20:13 by deryn.crockett