This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
howtos:model_loading [2010/01/22 20:46] deryn.crockett |
howtos:model_loading [2011/02/18 20:36] (current) deryn.crockett |
||
---|---|---|---|
Line 37: | Line 37: | ||
-Choose menu item FW Actions > Load OR right click and select Load (note the location is what you set in step 4) | -Choose menu item FW Actions > Load OR right click and select Load (note the location is what you set in step 4) | ||
-MB name: MUST be the model base name from the root of the simulation diagram, give it the description “sim” | -MB name: MUST be the model base name from the root of the simulation diagram, give it the description “sim” | ||
- | -Adjust your default file path to the cal location (e.g. /models/tcteem/V5/cal) | + | -Click OK to load the simulation framework |
- | -Repeat loading framework for cal BUT choose the check button to say it is a calibration framework, use the MB name from the calibration diagram, and enter "cal" as the description | + | -Choose menu item File > Set File Path... and direct it to the location of the calibrator files (e.g. /models/tcteem/V5/cal) |
+ | -Choose menu item FW Actions > Load OR right click and select Load again | ||
+ | -Enter the MB name from the calibration diagram, and enter "cal" as the description | ||
+ | -Activate the calibration framework check box | ||
+ | -Click OK to load the calibration framework | ||
-Load informants | -Load informants | ||
-Choose menu item Windows > Informants | -Choose menu item Windows > Informants | ||
- | -Right click and select Load (path should be correct because of 5c) | + | -Choose menu item Informant Actions > Load OR right click in Informants window and select Load |
- | -Adjust the file location if it is incorrect (should be something like /models/tcteem/V5/cal/informs.samm) | + | -Ensure the file path points to the cal location (the path should read something like /models/tcteem/V5/cal/informs.samm) |
+ | -Click OK to load the informants | ||
===== Run Calibration to Produce a History ===== | ===== Run Calibration to Produce a History ===== |